ASTM Complete Report Upon Request  >

TITLE: DESIGN PRESSURE

 

SUMMARY OF TEST RESULTS

Design Pressure ±4320 Pa (±90.23 psf)

Air Infiltration at 75 Pa (1.57 psf) 0.5 L/s/m2 (0.09 cfm/ft2)

Air Infiltration at 300 Pa (6.27 psf) 1.2 L/s/m2 (0.23 cfm/ft2)

Water Penetration Resistance Test Pressure 720 Pa (15.04 psf)

The specimens were evaluated in accordance with the following:

ASTM E283-04(2012), Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen.

ASTM E330/E330M-14, Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference.

ASTM E331-00(2016), Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference.

 

The temperature during testing was between 17°C - 19°C (63°F - 66°F). The results are tabulated as follows:

 

We are in Social